AFM Cantilevers & Probes

Atomic Force Microscopy Tips for Every Imaging Mode

Contact, tapping, liquid, MAC Mode, conductive, MFM and STM tips from Molecular Imaging. Compatible with all major brand AFM systems.

  • Probes for soft DNA, proteins, polymers and hard materials
  • Contact, tapping, liquid, conductive, MFM and STM tip options
  • Works with all major brand AFM systems

Built by the team behind the original Molecular Imaging AFM systems.

Prefer to talk? Call 1-888-644-0389

atomic force microscopy tips

Request AFM Probe Pricing

Tell us your imaging mode and sample. We will send pricing and the right tip options.

Which probes do you need? (select all that apply)

Your details go only to Molecular Imaging to answer your request. No spam. Privacy policy

25 Yearsof discovery and innovation
2018Molecular Imaging revived by former employees
All major brandsAFM systems our probes fit

Why researchers buy probes from us

One source for every mode

Contact, tapping, liquid, MAC Mode, conductive, MFM and diamond-coated probes in one place.

Fits your existing AFM

Our cantilevers and probes are compatible with all major brand AFM systems, not just ours.

Gentle on soft samples

MAC Mode paramagnetic levers use magnetic drive for low-force imaging of DNA and proteins in liquid.

Built for hard materials too

Diamond-coated indentation probes give wear resistance for hardness and mechanical testing.

Real AFM people to ask

Our team came from the original Molecular Imaging. Ask us which tip suits your sample.

Accessories to match

Add probe holders, nose cones, liquid cells, substrates and calibration standards to the same order.

AFM tips, cantilevers and probes we supply

Picking the wrong probe wastes samples and scan time. We stock cantilevers for contact, tapping and liquid modes, plus specialty tips for electrical, magnetic and mechanical measurements. Tell us your sample and mode and we will point you to the right part.

Probes ship as part of a full AFM parts line, so you can also order cantilever holders, nose cones, sample plates, mica and gold substrates and calibration standards at the same time.

  • Contact mode silicon cantilever ContSi-10 for topography and mechanical work
  • Contact mode silicon nitride cantilever S3N4-10 for durable contact imaging
  • Low frequency soft tapping FM-10, mid frequency NCL-30-10 and high frequency NCH-30-10
  • Liquid tapping Si3N4-L-10 for biological and polymer imaging in aqueous media
  • MAC Lever Types I, II, V, VI and VII with paramagnetic coating for MAC Mode in liquid
  • Conductive contact cantilevers for simultaneous topography and electrical measurement
  • MFM-10 cantilever for magnetic domain imaging
  • Diamond-coated Diamond-10 for indentation and hardness testing, tip height about 6 µm
  • STM tips: etched Pt-Ir, insulated Pt-Ir (under 70 pA) and tungsten probe tips

Get My Quote

AFM tips, cantilevers and probes we supply

What happens next

  1. Send your request

    Share your imaging mode, sample type and quantity through the form.

  2. We match the probe

    An AFM specialist confirms the cantilever or tip that fits your system and samples.

  3. You get pricing

    We send pricing for the probes and any holders, cells or standards you need.

Frequently asked questions

Do your probes work with non-Molecular Imaging AFMs?

Yes. Our cantilevers and probes are compatible with all major brand AFM systems.

How much do AFM tips cost?

Pricing is available on request for most cantilevers and probes. The STM Insulated Pt-Ir Tip PT-10 is listed at $10.00. Send your list and we will quote it.

Is there a minimum order?

Minimum order quantities are not set out here. Tell us how many probes you need and we will confirm what we can supply in your quote.

Which probe should I use for soft samples in liquid?

MAC Levers with paramagnetic coating are made for MAC Mode imaging of DNA, proteins and other soft samples in aqueous media. Liquid tapping Si3N4-L-10 is another option for biological and polymer samples.

Do you sell probes for electrical or magnetic measurements?

Yes. Conductive contact cantilevers support simultaneous topography and electrical property measurement, and the MFM-10 cantilever maps magnetic domains at the nanoscale.

Can I order holders and calibration samples too?

Yes. We supply cantilever holders and nose cones for standard, MAC Mode, STM, conductive and SECM use, plus mica and gold substrates, gratings and step-height standards.

Get the right AFM tips for your next scan

Tell us your imaging mode, sample and quantity. Our AFM team will match the probe and send pricing.

  • Probes for soft DNA, proteins, polymers and hard materials
  • Contact, tapping, liquid, conductive, MFM and STM tip options
  • Works with all major brand AFM systems

Prefer to talk? Call 1-888-644-0389

Which probes do you need? (select all that apply)

Your details go only to Molecular Imaging to answer your request. No spam. Privacy policy

Request AFM Probe Pricing

Tell us your imaging mode and sample. We will send pricing and the right tip options.

Which probes do you need? (select all that apply)

Your details go only to Molecular Imaging to answer your request. No spam. Privacy policy

Call Get My Quote